Paper Title :Comparison Of Acidic Decellularization Methods For Porcine Corneas
Author :Hung-Jun Lin, Chon-Ho Yen, Ching-Fu Tu, Der-Zen Liu
Article Citation :Hung-Jun Lin ,Chon-Ho Yen ,Ching-Fu Tu ,Der-Zen Liu ,
(2015 ) " Comparison Of Acidic Decellularization Methods For Porcine Corneas " ,
International Journal of Advances in Science, Engineering and Technology(IJASEAT) ,
pp. 5-8,
Special Issue-4, Nov.
Abstract : Corneal diseases are one of the main causes of vision loss worldwide. Although cornea transplantation is a very
useful treatment, the demand of corneas evidently exceeds the available supplement. Decellular corneal xenografts are
thought to be potential resources for human corneas substitutes. In this work, we compared different acidic decellular
protocols on porcine corneas. The porcine corneas were soaking in different concentrations of formic acid, acetic acid and
citric acid solutions at 25℃ for 24 h on an orbital shaker. These acidic decellular porcine corneal scaffolds (dPC) were
examined by scanning electronic microscope and showed uniform parallel extra cellular matrix structure and the average
microstructure pore size was 220±20 μm. According to DNA content, these acidic methods had great decellular efficiency.
Examined by Masson trichrome staining, the collagen fibers arrangement was found similarly between control group and
dPCs groups; and by Alcian blue staining, also confirmed that dPCs had an intact glycosaminoglycan preservation. These
results revealed that acidic decelluarization for porcine corneas provided great microstructure and biological properties for
further in vitro and in vivo tests, and suggested that acidic decellular scaffolds could have the potential for corneal tissue
engineering applications.
Keywords- Tissue Engineering, Scaffold, Decellularization, Pig, Corneal Xenograft.